千家信息网

如何保护Kubernetes Critical Pod

发表于:2025-12-01 作者:千家信息网编辑
千家信息网最后更新 2025年12月01日,这篇文章主要讲解了"如何保护Kubernetes Critical Pod",文中的讲解内容简单清晰,易于学习与理解,下面请大家跟着小编的思路慢慢深入,一起来研究和学习"如何保护Kubernetes
千家信息网最后更新 2025年12月01日如何保护Kubernetes Critical Pod

这篇文章主要讲解了"如何保护Kubernetes Critical Pod",文中的讲解内容简单清晰,易于学习与理解,下面请大家跟着小编的思路慢慢深入,一起来研究和学习"如何保护Kubernetes Critical Pod"吧!

Kubelet Eviction Manager Admit

kubelet在syncLoop中每个1s会循环调用syncLoopIteration,从config change channel | pleg channel | sync channel | houseKeeping channel | liveness manager's update channel中获取event,然后分别调用对应的event handler进行处理。

  • configCh: dispatch the pods for the config change to the appropriate handler callback for the event type

  • plegCh: update the runtime cache; sync pod

  • syncCh: sync all pods waiting for sync

  • houseKeepingCh: trigger cleanup of pods

  • liveness manager's update channel: sync pods that have failed or in which one or more containers have failed liveness checks

特别提一下,houseKeeping channel是每隔houseKeeping(10s)时间就会有event,然后执行HandlePodCleanups,执行以下清理操作:

  • Stop the workers for no-longer existing pods.(每个pod对应会有一个worker,也就是goruntine)

  • killing unwanted pods

  • removes the volumes of pods that should not be running and that have no containers running.

  • Remove any orphaned mirror pods.

  • Remove any cgroups in the hierarchy for pods that are no longer running.

pkg/kubelet/kubelet.go:1753func (kl *Kubelet) syncLoopIteration(configCh <-chan kubetypes.PodUpdate, handler SyncHandler,        syncCh <-chan time.Time, housekeepingCh <-chan time.Time, plegCh <-chan *pleg.PodLifecycleEvent) bool {        select {        case u, open := <-configCh:                                if !open {                        glog.Errorf("Update channel is closed. Exiting the sync loop.")                        return false                }                switch u.Op {                case kubetypes.ADD:                                                handler.HandlePodAdditions(u.Pods)                ...                case kubetypes.RESTORE:                        glog.V(2).Infof("SyncLoop (RESTORE, %q): %q", u.Source, format.Pods(u.Pods))                        // These are pods restored from the checkpoint. Treat them as new                        // pods.                        handler.HandlePodAdditions(u.Pods)                ...                }                if u.Op != kubetypes.RESTORE {                        ...                }        case e := <-plegCh:                ...        case <-syncCh:                ...        case update := <-kl.livenessManager.Updates():                ...        case <-housekeepingCh:                ...        }        return true}

syncLoopIteration中定义了当kubelet配置变更重启后的逻辑:kubelet会对正在running的Pods进行Admission处理,Admission的结果有可能会让该Pod被本节点拒绝。

HandlePodAdditions就是用来处理Kubelet ConficCh中的event的Handler。

// HandlePodAdditions is the callback in SyncHandler for pods being added from a config source.func (kl *Kubelet) HandlePodAdditions(pods []*v1.Pod) {        start := kl.clock.Now()        sort.Sort(sliceutils.PodsByCreationTime(pods))        for _, pod := range pods {                ...                if !kl.podIsTerminated(pod) {                        ...                        // Check if we can admit the pod; if not, reject it.                        if ok, reason, message := kl.canAdmitPod(activePods, pod); !ok {                                kl.rejectPod(pod, reason, message)                                continue                        }                }                ...        }}

如果该Pod Status不是属于Terminated,就调用canAdmitPod对该Pod进行准入检查。如果准入检查结果表示该Pod被拒绝,那么就会将该Pod Phase设置为Failed。

pkg/kubelet/kubelet.go:1643func (kl *Kubelet) canAdmitPod(pods []*v1.Pod, pod *v1.Pod) (bool, string, string) {        // the kubelet will invoke each pod admit handler in sequence        // if any handler rejects, the pod is rejected.        // TODO: move out of disk check into a pod admitter        // TODO: out of resource eviction should have a pod admitter call-out        attrs := &lifecycle.PodAdmitAttributes{Pod: pod, OtherPods: pods}        for _, podAdmitHandler := range kl.admitHandlers {                if result := podAdmitHandler.Admit(attrs); !result.Admit {                        return false, result.Reason, result.Message                }        }        return true, "", ""}

canAdmitPod就会调用kubelet启动时注册的一系列admitHandlers对该Pod进行准入检查,其中就包括kubelet eviction manager对应的admitHandle。

pkg/kubelet/eviction/eviction_manager.go:123// Admit rejects a pod if its not safe to admit for node stability.func (m *managerImpl) Admit(attrs *lifecycle.PodAdmitAttributes) lifecycle.PodAdmitResult {        m.RLock()        defer m.RUnlock()        if len(m.nodeConditions) == 0 {                return lifecycle.PodAdmitResult{Admit: true}        }                if utilfeature.DefaultFeatureGate.Enabled(features.ExperimentalCriticalPodAnnotation) && kubelettypes.IsCriticalPod(attrs.Pod) {                return lifecycle.PodAdmitResult{Admit: true}        }        if hasNodeCondition(m.nodeConditions, v1.NodeMemoryPressure) {                notBestEffort := v1.PodQOSBestEffort != v1qos.GetPodQOS(attrs.Pod)                if notBestEffort {                        return lifecycle.PodAdmitResult{Admit: true}                }        }                return lifecycle.PodAdmitResult{                Admit:   false,                Reason:  reason,                Message: fmt.Sprintf(message, m.nodeConditions),        }}

eviction manager的Admit的逻辑如下:

  • 如果该node的Conditions为空,则Admit成功;

  • 如果enable了ExperimentalCriticalPodAnnotation Feature Gate,并且该Pod是Critical Pod(Pod有Critical的Annotation,或者Pod的优先级不小于SystemCriticalPriority),则Admit成功;

    • SystemCriticalPriority的值为2 billion。

  • 如果该node的Condition为Memory Pressure,并且Pod QoS为非best-effort,则Admit成功;

  • 其他情况都表示Admit失败,即不允许该Pod在该node上Running。

Kubelet Eviction Manager SyncLoop

另外,在kubelet eviction manager的syncLoop中,也会对Critical Pod有特殊处理,代码如下。

pkg/kubelet/eviction/eviction_manager.go:226// synchronize is the main control loop that enforces eviction thresholds.// Returns the pod that was killed, or nil if no pod was killed.func (m *managerImpl) synchronize(diskInfoProvider DiskInfoProvider, podFunc ActivePodsFunc) []*v1.Pod {        ...        // we kill at most a single pod during each eviction interval        for i := range activePods {                pod := activePods[i]                                if utilfeature.DefaultFeatureGate.Enabled(features.ExperimentalCriticalPodAnnotation) &&                        kubelettypes.IsCriticalPod(pod) && kubepod.IsStaticPod(pod) {                        continue                }                ...                return []*v1.Pod{pod}        }        glog.Infof("eviction manager: unable to evict any pods from the node")        return nil}

当触发了kubelet evict pod时,如果该pod满足以下所有条件时,将不会被kubelet eviction manager kill掉。

  • 该Pod Status不是Terminated;

  • Enable ExperimentalCriticalPodAnnotation Feature Gate;

  • 该Pod是Critical Pod;

  • 该Pod时Static Pod;

感谢各位的阅读,以上就是"如何保护Kubernetes Critical Pod"的内容了,经过本文的学习后,相信大家对如何保护Kubernetes Critical Pod这一问题有了更深刻的体会,具体使用情况还需要大家实践验证。这里是,小编将为大家推送更多相关知识点的文章,欢迎关注!